How to calibrate the Hach Turbidity Meter SC200
The Hach Turbidity Meter SC200 is a reliable and accurate instrument used to measure the turbidity of water. Turbidity is a measure of the cloudiness or haziness of a fluid caused by suspended particles. It is an important parameter in water quality monitoring as it can indicate the presence of contaminants or pollutants in the water.
Calibrating the Hach Turbidity Meter SC200 is essential to ensure accurate and precise measurements. Calibration is the process of adjusting the instrument to a known standard or reference value. This ensures that the readings obtained from the meter are reliable and consistent.
To calibrate the Hach Turbidity Meter SC200, you will need a calibration kit that includes a set of standard turbidity solutions. These solutions have known turbidity values and are used to calibrate the meter. Before starting the calibration process, make sure that the meter is clean and free from any debris or residue that could affect the readings.
To begin the calibration process, first, prepare the standard turbidity solutions according to the manufacturer’s instructions. These solutions should cover a range of turbidity values to ensure that the meter is calibrated across its entire measurement range. Once the solutions are prepared, pour them into clean, clear glass vials.
Model | EC-810 Conductivity/Resistivity Controller |
Range | 0-200/2000/4000/10000uS/cm |
0-20/200mS/cm 0-18.25M\\u03a9 | |
Accuracy | Conductivity:1.5%;\\u00a0 Resistivity:2.0%(FS) |
Temp. Comp. | Automatic temperature compensation based on 25\\u2103 |
Oper. Temp. | Normal 0\\uff5e50\\u2103; High temp 0\\uff5e120\\u2103 |
Sensor | 0.01/0.02/0.1/1.0/10.0cm-1 |
Display | LCD Screen |
Current Output | 4-20mA output/2-10V/1-5V |
Output | High/Low limit dual relay control |
Power | AC 220V\\u00b110% 50/60Hz or AC 110V\\u00b110% 50/60Hz or DC24V/0.5A |
Working Environment | Ambient temperature:0\\uff5e50\\u2103 |
Relative humidity\\u226485% | |
Dimensions | 96\\u00d796\\u00d7100mm(H\\u00d7W\\u00d7L) |
Hole Size | 92\\u00d792mm(H\\u00d7W) |
Installation Mode | Embedded |
Next, turn on the Hach Turbidity Meter SC200 and allow it to warm up for a few minutes. Once the meter is ready, insert the first standard turbidity solution into the sample chamber and close the lid securely. The meter will automatically detect the solution and display the turbidity value on the screen.
Compare the reading on the meter to the known turbidity value of the standard solution. If there is a discrepancy between the two values, you will need to adjust the calibration settings on the meter. Most Hach Turbidity Meters SC200 have a calibration mode that allows you to enter the known turbidity value of the standard solution and adjust the calibration accordingly.
Repeat this process for each standard turbidity solution in the calibration kit, adjusting the calibration settings as needed. Once all the solutions have been tested and the meter is calibrated across its entire measurement range, the calibration process is complete.
It is important to calibrate the Hach Turbidity Meter SC200 regularly to ensure accurate and reliable measurements. Environmental conditions, such as temperature and humidity, can affect the performance of the meter and may require more frequent calibration. Additionally, if the meter is dropped or damaged, it should be recalibrated before use to ensure accurate readings.
In conclusion, calibrating the Hach Turbidity Meter SC200 is a simple yet important process that ensures accurate and reliable measurements of water turbidity. By following the manufacturer’s instructions and using standard turbidity solutions, you can calibrate the meter effectively and maintain the quality of your water quality monitoring data. Regular calibration will help to ensure that your measurements are accurate and consistent, allowing you to make informed decisions about water quality and environmental protection.