Table of Contents
Dry Type vs. Oil Filled Transformers: A Comparison
Transformers are an essential component in the electrical distribution system, responsible for stepping up or stepping down voltage levels to ensure efficient power transmission. When it comes to transformers, there are two main types: dry type and oil-filled transformers. Each type has its own set of advantages and disadvantages, making it important for businesses to carefully consider their specific needs before making a decision.
Dry type transformers, as the name suggests, do not use oil as a cooling medium. Instead, they rely on air or other gases to dissipate heat generated during operation. This makes them a popular choice for indoor applications where the use of oil may pose a safety hazard. Dry type transformers are also known for their low maintenance requirements and environmental friendliness, as they do not require regular oil testing and replacement.
On the other hand, oil-filled transformers use oil as a cooling medium to dissipate heat more effectively. This allows them to handle higher power loads and operate more efficiently than dry type transformers. However, the use of oil also comes with its own set of challenges, such as the need for regular oil testing and maintenance to ensure optimal performance and prevent potential hazards.
When comparing dry type and oil-filled transformers, businesses should consider factors such as cost, maintenance requirements, efficiency, and safety. While dry type transformers may have lower upfront costs and maintenance requirements, oil-filled transformers offer higher efficiency and power handling capabilities. Ultimately, the choice between the two types will depend on the specific needs and priorities of the business.
In China, there are many enterprises specializing in the manufacturing of medium voltage transformers, including both dry type and oil-filled transformers. These companies have years of experience in designing and producing high-quality transformers that meet international standards and specifications. With a focus on innovation and technology, Chinese transformer manufacturers have become leaders in the industry, providing reliable and efficient solutions for a wide range of applications.

One such enterprise is a specialist in medium voltage transformers with over 12 years of experience in the field. This company has a proven track record of delivering high-quality transformers that meet the needs of their customers. With a team of skilled engineers and technicians, they are able to design and manufacture transformers that are tailored to the specific requirements of each project.
To showcase their expertise and capabilities, this Chinese enterprise has produced a series of videos highlighting their manufacturing process and quality control procedures. These videos provide a behind-the-scenes look at how transformers are designed, tested, and assembled, giving customers confidence in the reliability and performance of the products.
| Type | Rated\\u00a0power\\u00a0\\uff08KVA\\uff09 | Voltage\\u00a0combination\\uff08KV\\uff09 | No-load\\u00a0losses\\uff08W\\uff09 | Load\\u00a0losses\\uff08W\\uff09 | No-load\\u00a0current\\u00a0(%) | Short-circuit\\u00a0impedance\\u00a0(%) |
| S11-630 | 630 | 33,35/6.3,6.6,10.5,11 | 830 | 7870 | 1.10 | 6.5 |
| S11-800 | 800 | 33,35/6.3,6.6,10.5,11 | 980 | 9410 | 1.00 | 6.5 |
| S11-1000 | 1000 | 33,35/6.3,6.6,10.5,11 | 1150 | 11540 | 1.00 | 6.5 |
| S11-1250 | 1250 | 33,35/6.3,6.6,10.5,11 | 1410 | 13940 | 0.90 | 6.5 |
| S11-1600 | 1600 | 33,35/6.3,6.6,10.5,11 | 1700 | 16670 | 0.80 | 6.5 |
| S11-2000 | 2000 | 33,35/6.3,6.6,10.5,11 | 2180 | 18380 | 0.70 | 6.5 |
| S11-2500 | 2500 | 33,35/6.3,6.6,10.5,11 | 2560 | 19670 | 0.60 | 6.5 |
| S11-3150 | 3150 | 33,35/6.3,6.6,10.5,11 | 3040 | 23090 | 0.56 | 7.0 |
| S11-4000 | 4000 | 33,35/6.3,6.6,10.5,11 | 3620 | 27360 | 0.56 | 7.0 |
| S11-5000 | 5000 | 33,35/6.3,6.6,10.5,11 | 4320 | 31380 | 0.48 | 7.0 |
| S11-6300 | 6300 | 33,35/6.3,6.6,10.5,11 | 5250 | 35060 | 0.48 | 7.5 |
| S11-8000 | 8000 | 33,35/6.3,6.6,10.5,11 | 7200 | 38500 | 0.42 | 7.5 |
| S11-10000 | 10000 | 33,35/6.3,6.6,10.5,11 | 8700 | 45300 | 0.42 | 7.5 |
| S11-12500 | 12500 | 33,35/6.3,6.6,10.5,11 | 10080 | 53900 | 0.40 | 8.0 |
| S11-16000 | 16000 | 33,35/6.3,6.6,10.5,11 | 12160 | 65800 | 0.40 | 8.0 |
| S11-20000 | 20000 | 33,35/6.3,6.6,10.5,11 | 14400 | 79500 | 0.40 | 8.0 |
| S11-25000 | 25000 | 33,35/6.3,6.6,10.5,11 | 17020 | 94100 | 0.32 | 8.0 |
| S11-31500 | 31500 | 33,35/6.3,6.6,10.5,11 | 20220 | 112900 | 0.32 | 8.0 |
| model | Rated\\u00a0power\\u00a0\\uff08KVA\\uff09 | Voltage\\u00a0combination\\uff08KV\\uff09 | No-load\\u00a0losses\\uff08W\\uff09 | Load\\u00a0losses\\uff08W\\uff09 | No-load\\u00a0current\\u00a0\\uff08%\\uff09 | Short-circuit\\u00a0impedance\\u00a0\\uff08%\\uff09 |
| SZ11-2000 | 2000 | 33,35/6.3,6.6,10.5,11 | 2300 | 19240 | 0.80 | 6.5 |
| SZ11-2500 | 2500 | 33,35/6.3,6.6,10.5,11 | 2720 | 20640 | 0.80 | 6.5 |
| SZ11-3150 | 3150 | 33,35/6.3,6.6,10.5,11 | 3230 | 24710 | 0.72 | 7.0 |
| SZ11-4000 | 4000 | 33,35/6.3,6.6,10.5,11 | 3870 | 29160 | 0.72 | 7.0 |
| SZ11-5000 | 5000 | 33,35/6.3,6.6,10.5,11 | 4640 | 34200 | 0.68 | 7.0 |
| SZ11-6300 | 6300 | 33,35/6.3,6.6,10.5,11 | 5630 | 36800 | 0.68 | 7.5 |
| SZ11-8000 | 8000 | 33,35/6.3,6.6,10.5,11 | 7870 | 40600 | 0.60 | 7.5 |
| SZ11-10000 | 10000 | 33,35/6.3,6.6,10.5,11 | 9280 | 48100 | 0.60 | 7.5 |
| SZ11-12500 | 12500 | 33,35/6.3,6.6,10.5,11 | 10940 | 56900 | 0.56 | 8.0 |
| SZ11-16000 | 16000 | 33,35/6.3,6.6,10.5,11 | 13170 | 70300 | 0.54 | 8.0 |
| SZ11-20000 | 20000 | 33,35/6.3,6.6,10.5,11 | 15570 | 82800 | 0.54 | 8.0 |
In conclusion, when it comes to choosing between dry type and oil-filled transformers, businesses should carefully consider their specific needs and priorities. While dry type transformers may offer lower maintenance requirements and environmental benefits, oil-filled transformers provide higher efficiency and power handling capabilities. With the expertise and experience of Chinese transformer manufacturers, businesses can find reliable and efficient solutions for their electrical distribution needs.